AMNETPRO Project · Smart Metering

AMIR MicroMetering & Pulse Conversion

Canada

AMNETPRO developed the AMIR Micro family as custom industrial metering hardware that receives and validates pulse signals from existing water meters, calculates flow and accumulated volume, and provides configurable Pulse Out and UI1203 interfaces without replacing the original meter.

Location

Canada

Sector

Water & Metering

Solution

Custom Edge Hardware

Integration

Existing Water Meters

Engineering Challenge

Useful meter signals already existed. The challenge was to turn them into reliable metering information and usable downstream interfaces.

Existing water meters generated pulse signals that already represented valuable consumption information.

The engineering problem was not how to replace the meter. It was how to validate and process its existing pulse signal reliably, calculate useful metering values, and make those values available to downstream systems.

The solution therefore needed to preserve the existing metering infrastructure while making its information available to additional systems.

Engineering Principle

Build around what already works.

AMNETPRO did not treat the existing meter as a problem simply because a new digital requirement appeared.

Instead, the engineering focused on extending the value of the existing asset.

The goal was to create new capability without creating unnecessary replacement cost.

Engineering Approach

Validate the pulse. Calculate the measurement. Deliver it where it is needed.

AMNETPRO developed dedicated edge hardware capable of receiving meter pulses, validating accepted signals, maintaining pulse counts and calculating flow and accumulated volume from the configured metering scale.

The resulting metering information can then be exposed through configurable Pulse Out and UI1203 interfaces while the original meter remains in service.

Custom Industrial Hardware
Edge Processing
Pulse Validation
Flow & Volume Calculation
Smart Metering
Configurable Pulse Out
UI1203 Integration
Existing Infrastructure Reuse

Implemented Solution

Existing meter signals. Multiple usable outputs.

AMIR Micro receives and validates meter pulses at the edge, then converts accepted pulse counts into accumulated volume and live flow.

Configurable Pulse Out can generate downstream pulse information from the accepted metering volume, while UI1203 provides a separate metering interface when required.

This allows downstream monitoring, control or metering environments to use the information without changing the original meter itself.

ROI-Driven Engineering→

Engineering Result

More metering capability without replacing the existing metering asset.

Existing meter retained
Pulse signals validated
Flow and volume calculated
Configurable Pulse Out available
UI1203 interface available
Downstream integration enabled
Edge-level processing
Reduced unnecessary replacement cost

What This Project Demonstrates

When standard industrial components do not satisfy an operational requirement, AMNETPRO can develop custom hardware that extends existing infrastructure instead of replacing it unnecessarily.

Let's Turn YourOperational ChallengeInto Measurable Value.

Tell us what you need to improve. Our engineering team will help you identify the clearest path from operational challenge to measurable return.

You bring the challenge. We build the solution.

General Inquiries

info@amnetpro.com

Alternate Contact

+57 316 617 1892

Prefer a direct conversation? Reach us by email, phone, or WhatsApp.